Microscale Managed Aquifer Recharge
ESF 05 & 12

Two ways of getting water back underground: hardpan breakers drilled through a dense layer in ESF 05, and a passive basin in ESF 12 that has taken about 2 acre-feet.
About this research
Two microscale Managed Aquifer Recharge trials run at the farm, each working with the geology of its own block to move surface water down into the groundwater.
In ESF 05 the obstacle is a hardpan horizon, a dense, low-permeability layer that all but stops water percolating. The team drilled eight vertical holes — 15 feet deep and 6 inches wide — through it at set points, each one a high-conductivity conduit from the shallow infiltration zone to the permeable strata below. A 50-foot monitoring well sits above a groundwater storage pocket identified earlier.
In ESF 12 the ground drains well enough to work with nature. Over 20 days the team ran 15 controlled flood events, putting roughly 2 acre-feet of water into the target pocket at 1 cm per hour.
Monitoring of infiltration rates, water table response and soil moisture across both blocks is planned, to quantify what each design achieves and how the approach might scale to similar ground.
Project details
- PI & team:
- Thomas Harmon; Humberto Flores, Yelenka Nunez Bolano and Andres Morande (graduate students)
- Department:
- Civil & Environmental Engineering
- Summer 2026 crop:
- Not applicable (ESF 05); pepper (ESF 12)